Weight Display: | |
---|---|
Serial Interface: | |
Mounting mode: | |
Accuracy: | |
Availability: | |
Quantity: | |
D360
ATRONTEC
D360 is a high accuracy Industrial Process Weighing Controller. This weighing controller has a variety of field bus communication with high reliability which can fully meet complicated and harsh requirements during industrial weighing control process.
Features:
* 5-step filter, high precision,high anti-vibration
* 3 housing modes: Panel、Harsh、Exd
* Harsh and Exd versions with seven bits 1” high green and red LED display and 10 status lights.
* Panel mount with seven bits 0.56” high green and red LED display and 10 status lights.
* Standard with two serial ports (RS232 and RS232/485), Kinds of field-bus options to connect to PLC or DCS
* Report Weight and rate at the same time from PROFIBUS-DP,MODBUS_RTU,
* 4-20mA, MODBUS-TCP
* 3 kinds PROFIBUS GSD inside
* UDP,TCP,MODBUS-TCP
* No-Testing Weight Calibration is available
* Zone:Zone 2, 22 and Div. 2 location
* Exd Class: EXD IIB T6
Options:
* 8 Inputs /12 Outputs (OC Type)
* 8 Inputs /12 Outputs (Relay Type)
* 4-20mA Output(16-bit DAC) x 1
* 4-20mA Output(16-bit DAC) x 2
* 100M LAN(TCP,UDP,MODBUS-TCP)
* POFIBUS DP for Siemens PLC
* PROFINET for Siemens PLC
* EtherNet/IP for Rockwall PLC
* CC-LINK for Mitsubishi PLC
Specifications:
Accuracy | |
Accuracy Class | III |
EU Approval | 150,000 Display Division ,CMC 6000e |
Display & Keypad | |
Display | 7 bits 7-segment green or red LED display, Exd and Harsh:1”high display(25.4mm) Panel: 0.56” high display(14.2mm) |
Update Speed | 50ms |
Status Display | Tare,Net,Motion,Center of Zero,Kg/Lb,PLC online/offline |
Key | 6 function keys(Memory,Tare, Clear,Zero,unit Switch,Print) SS keypad for Exd version |
Power On/Off | None |
Keypad Lock | Can be locked via local input or remote communication (MODBUS-RTU,MODBUS-TCP,PROFIBUS-DP, PROFINET, EtherNet/IP, CC-LINK) |
ADC | |
Type | 24-bit |
Speed | 200 Hz |
Resolution | 0.06uV/d |
Resolution Approved | 1uV/e(legal for trade) |
Input | 0.1mV to 19Mv |
Accuracy | 150,000d |
Linearity and Stability | |
In-linearity & TC | ≤0.0015% FS;≤5ppm/℃ |
Load Cell | |
Exciting Voltage | 5V DC, max 150mA |
Load Cell Number | Max 10 x 350Ω or 24 x 1100Ω |
Connect Type | 4- wired or 6-wired , Cable:274mR/m2 |
Scale Basic Functionality | |
Calibration | 2-point with testing weight or no testing(CalFree) |
Filter | 5-step |
Scale Process | Tare,Zero,Auto Zero,Motion, Auto Tare, Auto Clear, Auto Print |
Inputs | Option 8 Inputs,Can be assigned remote inputs for remote host(PLC or DCS) |
Outputs | Option 12 Outputs,Can be assigned remote outputs for remote host(PLC or DCS) |
Target Control | |
OVER/UNDER/OK | Support and other 8 comparators are available |
Zero Tolerance | Support |
Target Control | Simple Setpoint or Sequence Control(with Start & Abort command) |
Communication I/F | |
Serial Port | 2 ports:COM1-RS232, COM2-RS232/485, MODBUST-RTU, Continuous output weight, Demand Input & Demand Output |
PROFINET | Connect to Siemens PLC, report integer weight data and Floating weight data |
EtherNet/IP | Connect to Rockwall PLC, report integer weight data and Floating weight data |
MODBUS-RTU | Support, Integer & Floating weight data |
100M LAN Port | 100M,TCP,UDP,MODBUS-TCP |
Analog Output | 4-20mA(16-bit DAC) x1 or 4-20mA(16-bit DAC) x2 |
PROFIBUS-DP | Integer & Floating weight data, 100Hz updating speed, 3 GSD inside,Totally compatible to PANTHER & IND131/331 |
CC-LINK | for Mitsubishi PLC, Totally compatible to PANTHER & IND131/331 |
Housing | |
Panel Mount | IP65,0.56” display |
Harsh | IP69K, 1”display |
Exd | IP65, 1”display,Exd ib[ia II C Ga] IIB T6 Gb/DIP A21 TA,T6 |
DIN Rail | |
Working Condition | |
Temperature | -10℃~40℃ ,95% RH |
Power Supply | 86~264VAC,12W |
D360 is a high accuracy Industrial Process Weighing Controller. This weighing controller has a variety of field bus communication with high reliability which can fully meet complicated and harsh requirements during industrial weighing control process.
Features:
* 5-step filter, high precision,high anti-vibration
* 3 housing modes: Panel、Harsh、Exd
* Harsh and Exd versions with seven bits 1” high green and red LED display and 10 status lights.
* Panel mount with seven bits 0.56” high green and red LED display and 10 status lights.
* Standard with two serial ports (RS232 and RS232/485), Kinds of field-bus options to connect to PLC or DCS
* Report Weight and rate at the same time from PROFIBUS-DP,MODBUS_RTU,
* 4-20mA, MODBUS-TCP
* 3 kinds PROFIBUS GSD inside
* UDP,TCP,MODBUS-TCP
* No-Testing Weight Calibration is available
* Zone:Zone 2, 22 and Div. 2 location
* Exd Class: EXD IIB T6
Options:
* 8 Inputs /12 Outputs (OC Type)
* 8 Inputs /12 Outputs (Relay Type)
* 4-20mA Output(16-bit DAC) x 1
* 4-20mA Output(16-bit DAC) x 2
* 100M LAN(TCP,UDP,MODBUS-TCP)
* POFIBUS DP for Siemens PLC
* PROFINET for Siemens PLC
* EtherNet/IP for Rockwall PLC
* CC-LINK for Mitsubishi PLC
Specifications:
Accuracy | |
Accuracy Class | III |
EU Approval | 150,000 Display Division ,CMC 6000e |
Display & Keypad | |
Display | 7 bits 7-segment green or red LED display, Exd and Harsh:1”high display(25.4mm) Panel: 0.56” high display(14.2mm) |
Update Speed | 50ms |
Status Display | Tare,Net,Motion,Center of Zero,Kg/Lb,PLC online/offline |
Key | 6 function keys(Memory,Tare, Clear,Zero,unit Switch,Print) SS keypad for Exd version |
Power On/Off | None |
Keypad Lock | Can be locked via local input or remote communication (MODBUS-RTU,MODBUS-TCP,PROFIBUS-DP, PROFINET, EtherNet/IP, CC-LINK) |
ADC | |
Type | 24-bit |
Speed | 200 Hz |
Resolution | 0.06uV/d |
Resolution Approved | 1uV/e(legal for trade) |
Input | 0.1mV to 19Mv |
Accuracy | 150,000d |
Linearity and Stability | |
In-linearity & TC | ≤0.0015% FS;≤5ppm/℃ |
Load Cell | |
Exciting Voltage | 5V DC, max 150mA |
Load Cell Number | Max 10 x 350Ω or 24 x 1100Ω |
Connect Type | 4- wired or 6-wired , Cable:274mR/m2 |
Scale Basic Functionality | |
Calibration | 2-point with testing weight or no testing(CalFree) |
Filter | 5-step |
Scale Process | Tare,Zero,Auto Zero,Motion, Auto Tare, Auto Clear, Auto Print |
Inputs | Option 8 Inputs,Can be assigned remote inputs for remote host(PLC or DCS) |
Outputs | Option 12 Outputs,Can be assigned remote outputs for remote host(PLC or DCS) |
Target Control | |
OVER/UNDER/OK | Support and other 8 comparators are available |
Zero Tolerance | Support |
Target Control | Simple Setpoint or Sequence Control(with Start & Abort command) |
Communication I/F | |
Serial Port | 2 ports:COM1-RS232, COM2-RS232/485, MODBUST-RTU, Continuous output weight, Demand Input & Demand Output |
PROFINET | Connect to Siemens PLC, report integer weight data and Floating weight data |
EtherNet/IP | Connect to Rockwall PLC, report integer weight data and Floating weight data |
MODBUS-RTU | Support, Integer & Floating weight data |
100M LAN Port | 100M,TCP,UDP,MODBUS-TCP |
Analog Output | 4-20mA(16-bit DAC) x1 or 4-20mA(16-bit DAC) x2 |
PROFIBUS-DP | Integer & Floating weight data, 100Hz updating speed, 3 GSD inside,Totally compatible to PANTHER & IND131/331 |
CC-LINK | for Mitsubishi PLC, Totally compatible to PANTHER & IND131/331 |
Housing | |
Panel Mount | IP65,0.56” display |
Harsh | IP69K, 1”display |
Exd | IP65, 1”display,Exd ib[ia II C Ga] IIB T6 Gb/DIP A21 TA,T6 |
DIN Rail | |
Working Condition | |
Temperature | -10℃~40℃ ,95% RH |
Power Supply | 86~264VAC,12W |