Material: | |
---|---|
Protection: | |
Type: | |
Application: | |
Availability: | |
Quantity: | |
BM8D
Stainless Steel Shear Beam Load Cell for Platform Scales And Hopper Scales
Load Cell Features:
Stainless steel shear beam load cell (150kg and 300 kg are bending beam load cells)
Hermetically sealed IP68
This load cell is suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices
High accuracy
The load celll includes wide range of capacities.
Load Cell Data Sheet:
Accuracy class | C3 | C5 | C6 | B10S | A5M | B10M | |
Approvals | OIMLR60 C3 | OIMLR60 C5 | OIMLR60 C6 | ||||
Output sensitivity (=FS) | mV/V | 2.0 ± 0.004 | 3.0 ± 0.008 | ||||
Maximum capacity (Emax) | t | 0.1/0.15/0.2/0.25/0.3/0.5/1/1.5/2/2.5/3/5/7.5/10 | |||||
klb | 1/1.5/2/2.5KLE/3/4/5/5KSE/7.5/10/15/20 | ||||||
Maximum number of load cell intervals (nLC) | 3000 | 5000 | 6000 | IIIL10000 Single | III5000 Multiple | IIIL10000 Multiple | |
Ratio of minimum LC verification interval Y=Emax/vmin | 10000 | 18000 | 20000 | 10000 | 15000 | 10000 | |
Combined error | %FS | ± 0.020 | ± 0.010 | ± 0.009 | ± 0.035 | ± 0.026 | ± 0.050 |
Minimum dead load | %FS | 0 | |||||
Safe overload | %FS | 150 | |||||
Ultimate overload | %FS | 300 | |||||
Zero balance | %FS | ± 1.0 | |||||
Excitation, recommended voltage | V | 5 ~ 12( DC ) | |||||
Excitation maximum | V | 18( DC ) | |||||
Input resistance | Ω | 350 ± 3.5 | |||||
Output resistance | Ω | 350 ± 3.5 | |||||
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | |||||
Compensated temperature | ℃ | -10 ~+40 | |||||
Operating temperature | ℃ | -35 ~ +65 | |||||
Storage temperature | ℃ | -40 ~ +70 | |||||
Element material | Stainless steel | ||||||
Recommended torque on fixation | N.m | M12: 75 M20:450 M24:750 | |||||
Ingress protection (according to EN 60529) | IP68 | ||||||
ATEX classification (optional) | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ | II3G Ex nL IIC T4 |
How to choose the load cell according the working environment of weighing scales?
The load cell is actually a device that converts the quality signal into a measurable electrical signal.
When using a sensor, the actual working environment of the sensor must first be considered. This is very important for the correct selection of the load cell. It is related to whether the load cell can work normally, its safety and service life, and even the reliability and safety of the entire weighing scale as well.
In general, the high temperature environment will cause problems such as melting of the coating material, breakage of welding spots, and structural changes in the internal stress of the elastomer;
Dust and humidity will cause a short circuit to the load cell;
In a highly corrosive environment, it will cause load cell's elastic body damage or short circuit;
The electromagnetic field will interfere with the load cell output.
Under the corresponding environmental factors, we must choose the corresponding load cell to meet the necessary weighing requirements.
Stainless Steel Shear Beam Load Cell for Platform Scales And Hopper Scales
Load Cell Features:
Stainless steel shear beam load cell (150kg and 300 kg are bending beam load cells)
Hermetically sealed IP68
This load cell is suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices
High accuracy
The load celll includes wide range of capacities.
Load Cell Data Sheet:
Accuracy class | C3 | C5 | C6 | B10S | A5M | B10M | |
Approvals | OIMLR60 C3 | OIMLR60 C5 | OIMLR60 C6 | ||||
Output sensitivity (=FS) | mV/V | 2.0 ± 0.004 | 3.0 ± 0.008 | ||||
Maximum capacity (Emax) | t | 0.1/0.15/0.2/0.25/0.3/0.5/1/1.5/2/2.5/3/5/7.5/10 | |||||
klb | 1/1.5/2/2.5KLE/3/4/5/5KSE/7.5/10/15/20 | ||||||
Maximum number of load cell intervals (nLC) | 3000 | 5000 | 6000 | IIIL10000 Single | III5000 Multiple | IIIL10000 Multiple | |
Ratio of minimum LC verification interval Y=Emax/vmin | 10000 | 18000 | 20000 | 10000 | 15000 | 10000 | |
Combined error | %FS | ± 0.020 | ± 0.010 | ± 0.009 | ± 0.035 | ± 0.026 | ± 0.050 |
Minimum dead load | %FS | 0 | |||||
Safe overload | %FS | 150 | |||||
Ultimate overload | %FS | 300 | |||||
Zero balance | %FS | ± 1.0 | |||||
Excitation, recommended voltage | V | 5 ~ 12( DC ) | |||||
Excitation maximum | V | 18( DC ) | |||||
Input resistance | Ω | 350 ± 3.5 | |||||
Output resistance | Ω | 350 ± 3.5 | |||||
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | |||||
Compensated temperature | ℃ | -10 ~+40 | |||||
Operating temperature | ℃ | -35 ~ +65 | |||||
Storage temperature | ℃ | -40 ~ +70 | |||||
Element material | Stainless steel | ||||||
Recommended torque on fixation | N.m | M12: 75 M20:450 M24:750 | |||||
Ingress protection (according to EN 60529) | IP68 | ||||||
ATEX classification (optional) | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ | II3G Ex nL IIC T4 |
How to choose the load cell according the working environment of weighing scales?
The load cell is actually a device that converts the quality signal into a measurable electrical signal.
When using a sensor, the actual working environment of the sensor must first be considered. This is very important for the correct selection of the load cell. It is related to whether the load cell can work normally, its safety and service life, and even the reliability and safety of the entire weighing scale as well.
In general, the high temperature environment will cause problems such as melting of the coating material, breakage of welding spots, and structural changes in the internal stress of the elastomer;
Dust and humidity will cause a short circuit to the load cell;
In a highly corrosive environment, it will cause load cell's elastic body damage or short circuit;
The electromagnetic field will interfere with the load cell output.
Under the corresponding environmental factors, we must choose the corresponding load cell to meet the necessary weighing requirements.