Maximum capacity | kg | 600 |
|
|
| t |
| 1、2、3 | 5、10/20 |
|
|
|
|
|
Sensitivity | mV/V | 2.0±0.004 | 3.0±0.004 | 2.0±0.004 |
Accuracy class |
| C3 | C2 |
Maximum number of load cell interval |
| 3000 | 2000 |
Minimum load cell verification interval |
| Emax /10000 | Emax /7000 |
Combined error | %F.S. | 0.02 | 0.023 |
Repeatability | %F.S. | 0.01 | 0.015 |
Creep %F.S./30min | %F.S./30min | ±0.0245 | ±0.0245 |
Minimum dead load output return | %F.S. | ±0.017 | ±0.025 |
Temp. effect on min. dead load output | %F.S./5℃ | ±0.007 | ±0.010 |
Temp. effect on sensitivity | %F.S./5℃ | ±0.007 | ±0.009 |
Minimum dead load | % Emax | 1 |
Maximum safe overload | % Emax | 150 |
Ultimate overload | % Emax | 200 |
Supply voltage | V | 5 ~ 15(DC/AC) |
Zero balance | %F.S. | ±1 |
Input resistance | Ω | 380 ~ 440 | 390 ~ 440 |
Output resistance | Ω | 349 ~ 355 |
Insulation resistance | MΩ | ≥5000 |
Compensated temperature range | ℃ | -10 ~ +40 |
Operating temperature range | ℃ | -30 ~ +70 |
Connect cable | mm | 600 kg 、1t、2t、3t:Φ4.7×7500(4-core) |
5t:Φ4.7×9000(4-core) |
10t、20t: Φ6.7×10000(6-core) |
Method of connecting wire | 4-core:Input: Red(+), White(-);Output: Green(+), Blue(-) |
Shield :Yellow |
6-core: Input: Green(+), Black(-); Feedback: Yellow(+), Blue(-); |
Output: White(+), Red(-); Shield :Yellow |